Other Requirements
Rules
- The septic tank system shall be maintained at all times to prevent seepage or discharge of sewage or effluent to the surface of the ground or to surface waters.
- The area approved for the installation of the septic tank system must be left in an undisturbed state. Disturbances of this area may result in revocation of the improvement permit.
- The septic tank must be inspected and approved by a representative of Environmental Health before any portion of the installation is covered. The septic tank system shall not be put into use until an Operation Permit has been issued.
- The repair area must remain in a natural state. No permanent structure or alterations shall be made (such as removal of soil or installing a driveway).
- The area in which nitrification field is installed must be landscaped properly to prevent ponding of surface water. Run-off or surface water shall be diverted away from the nitrification field.
- Unless otherwise indicated, drain lines shall be installed on 9' centers.
- At least 6" of approved soil shall be placed over any portion of the drain field with less than 18" trench depth.
Minimum Distances from Septic Tank
|
Item |
Distance from Septic Tank |
| Private water supplies |
100 ft. |
| Public water supply sources |
100 ft. |
| Building foundations |
5 ft. |
| Basements |
15 ft. |
| Property lines |
10 ft. |
| Embankments or cuts |
15 ft. |
| Water lines |
10 ft. |
| Swimming pools |
15 ft. |
| Groundwater lowering ditches or devices |
25 ft. |
| Other sewage disposal systems |
20 ft. | Do not build, park, or drive over a septic tank system.
|
|